The lead-acid maintenance-free VLRA batteries of the ExeGate EL series are manufactured using GEL technology, are completely sealed and maintenance-free. Due to their design, they are suitable for equipment that requires a reliable power source under high loads and non-standard conditions. With proper operation, gel batteries retain their capacity and functionality for a long time, which makes them in demand among users who need a reliable and durable battery. To extend the service life and maintain the working condition of the battery, it is important to follow the recommendations for chargin

The case is made of plastic, which does not support combustion and prevents leakage of electrolyte.Gorenje Double sealing of terminals. The batteries are equipped with an internal gas recombination system, do not require refilling water, are resistant to corrosion and deep discharges, have a long service life and a wide range of operating temperatures. Comply with the requirements of the UL directive. Operation in different positions is acceptable without loss of productivity.

Specification

AppointmentFor UPS
Voltage, V12
Battery capacity, Ah55
Standards and certificationsDeclaration of conformity GOST 12.2.007.12-88;
GOST R IEC 61056-1-2012 Pn. 4.1.2 - 4.1.4, 4.4, 5.4, 5.7 - 5.10;
GOST R IEC 60896-22-2015 Clause 4.2,4.3,4.4
Battery Life
In buffered mode16 years (at 25°C)
Cyclic mode1200 cycles at 30% depth of discharge
Number of charge-discharge cycles in cyclic mode at 100% discharge240
Self-discharge3% per month at 20°C
Charge methodConstant voltage charge (25°C)
Cyclic mode2.4 - 2.5 V / cell
Buffer mode2.25 - 2.3 V / cell
Internal resistance of a fully charged battery (25°C), m?10
Cabinet materialABS plastic
Temperature modes
Storagefrom -15°C to + 50°C
Chargefrom -10°C to + 50°C
Dischargefrom -20°C to + 50°C
Warranty12 months if operating conditions are observed
Terminal typeM6 bolt
Maximum discharge current (25°C)165A(5c)
Height with terminal, mm210
Delivery setBattery
Product size, mm132x205x229
Weight, kg16,5
P/NEX301506
EAN4895205105188