UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH

UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
UPS (inverter, sine, for boiler, PF 1, wall-mounted) ExeGate IdealSine SR-600.LCD.2SH
Line-interactive UPS IdealSine series have a high power density (W= VA), provide a sinusoidal voltage of strictly regular shape (pure sine wave) at the output, which makes them an ideal choice for power supply of boilers, pumps, medical and other equipment demanding on the quality of supply voltage.

The high power factor (PF=1) ensures maximum performance of the Ideal Line series UPS. External batteries are required for operation. Internal batteries are not provided.

Specification

TypeUPS
Type of UPSOff-Grid
Full power capacity, VA600
Active power capacity, W600
Power Factor (PF)1
Efficiency (AC mode), %> 95
Output connector2xSchuko
Input
Input connectionEuroplug with grounding. Detachable cable.
Cable length, m1,2
Battery Voltage220Vac±5%
Input voltage range for mains operation, V170-270
Input frequency, Hz45-65
Output
Nominal output voltage, V220Vac ±5% for battery mode;170V-270 for AC mode
Output frequency, Hz50/60±0.5 for battery mode;45-65 for AC mode
Waveform typePure sine wave
Protection
Surge Protection at line modeShutdown after 5 min when the load is > 110%
Batteries and battery life
Battery Voltage12
Battery typeSealed lead-acid battery, maintenance-free
Battery capacity and battery quantity, Ah26-200 (must be purchased additionally)
Cold startYes
Charge Current20
Battery cable length, m0,7
TerminalsM6
Indicators and signals
Indicator typeLCD
Other parameters
Operating Temperature0-40 C
Storage Tempetature- 15 - 45 C
Operating Relative Humidity10-90%
Cabinet colorBlack
Cabinet madeSteel
Dimensions, mm330x210x105
Package dimensions, mm390x260x155
Net weight, kg3
Gross weight, kg3,94
Delivery setUPS, bracket, battery cables, Power cable, user manual